Model No.: HVD7 Brand Name: Jucro
Certification: iso9001
Specification: Rated voltage: 33kv 36KV

1 minute power frequency withstand voltage, dry test: 95 kv

1 minute power frequency withstand voltage, wet test: 80 kv

Lightning impulse withstand voltage(peak value): 185 kv

Rated current: 1600A / 2000A

Rated short-circuit breaking current: 20KA, 25KA, 31.5KA

Rated short-circuit making current(peak): 50KA, 63KA, 80KA

Rated operating sequence: O-0.3s-CO-180s-CO

Rated short-time withstand current: 20KA, 25KA, 31.5KA

Rated peak withstand current: 50KA, 63KA, 80KA

Rated short-circuit duration: 4 s

Rated control voltage: AC220,110;DC220,110

Rated short-circuit breaking current break times: 20 times

Full-break time: <80 ms

Mechanical life: 10,000 times
Packaging & Delivery
Packaging: carton
Delivery/Lead Time: 2 weeks
Production Capacity: 5000
Product Description
1. Introduction

HVD7 33KV 36kv outdoor HV AC vacuum circuit breaker VCB has many visual advantages like reasonable design, fashionable appearance, high safety and reliability, simple maintenance, long electric life. It is the ideal upgraded products of 35KV outdoor oil circuit breakers.

HVD7-40.5 vacuum circuit breaker is applicable for three-phase power system of AC 50HZ.It is used to make and break the load current ,overload current and short-circuit current.



2. Applicable environment

3.1The ambient temperature should be -30degree~ +40degree(-40degree in the frosty area);

3.2Altitude should not exceed 2000m(over 2000m is plateau type);

3.3The wind pressure should not exceed 700Pa(equal to wind speed 34m/s);

3.4Air pollution degree: 3,that of antifouling type:4;

3.5The installation site should be free from the fire, explosion, chemical corrosion and serious vibration.





Main technical parameters
Rated voltage: 33kv 36KV

1 minute power frequency withstand voltage, dry test: 95 kv

1 minute power frequency withstand voltage, wet test: 80 kv

Lightning impulse withstand voltage(peak value): 185 kv

Rated current: 1600A / 2000A

Rated short-circuit breaking current: 20KA, 25KA, 31.5KA

Rated short-circuit making current(peak): 50KA, 63KA, 80KA

Rated operating sequence: O-0.3s-CO-180s-CO

Rated short-time withstand current: 20KA, 25KA, 31.5KA

Rated peak withstand current: 50KA, 63KA, 80KA

Rated short-circuit duration: 4 s

Rated control voltage: AC220,110;DC220,110

Rated short-circuit breaking current break times: 20 times

Full-break time: <80 ms

Mechanical life: 10,000 times
VCB vacuum circuit breaker HVD7

SUPPLIER PROFILE
Company: hubei jucro electric co.,ltd
City/State zhijiang, yichang Country: China  
Business Type: Export - Manufacturer / Trading Company Established: 2010
Member Since: 2018 Contact Person lucy lu
SUPPLIER PROFILE
City/State/Country -
zhijiang, yichang
China  
Business Type -
Export - Manufacturer / Trading Company
Established -
2010
Member Since -
2018
Contact Person -
lucy lu