Advertisements
Konan Intrinsic Safety 454 series 5-port solenoid valves spool valve
| Price: | US$ 420 / Piece |
|---|---|
| Minimum Order: | 1pc |
| Payment Terms: | T/T |
| Port of Export: | China |
Product Details
| Model No.: | S202JF02L7DG4 | Brand Name: | Konan Electric Co., Ltd |
|---|
| Certification: | COC |
|---|---|
| Specification: |
Intrinsic safety valves can be used for applications that require similar explosion class/ignition degree to d2G4 or Exd II BT5 type (explosion-proof enclosure construction). Without need for expensive connection tools and complex installation work that are inevitable for explosion-proof enclosure types, the intrinsic safety valves achieve highly reliable explosion-proof performance.
Return Hold Kind of barrier to combine 454S202C 454S203C 454S403C 454S404C 454D202C 454D203C 454D403C 454D404C SAF3-5 454S202M 454S203M 454S403M 454S404M 454D202M 454D203M 454D403M 454D404M In the case of other explosion-proof barriers and combination *1 Structure of the main valve Pilot spool type Port size Rc1/4 Rc3/8 Rc1/2 Rc1/4 Rc3/8 Rc1/2 Effective area of valve 22mm2 40mm 22mm 40mm2 Working pressure 0.2~0.7MPa Ambient temp. -5~50℃ Explosion-proof standard Intrinsic safety construction Operating condition Use with specified safety barrier For i2G4 explosion-proof valves, use them with MTL728+ safety barrier. For Exia II BT5 explosion-proof valves, use them with the safety barrier SAF3-5 or that meets the conditions described below (note *1). 2. Parts and connections cannot be changed. 3. Use 1 explosion-proof barrier for each solenoid valve. 12. Konan Intrinsic Safety Solenoid Valves 414/416 series 5-port solenoid valves Terminal block ZA Spool valve/Ceramic slide valve Return Kind of barrier to combine ExiaⅡBT5 SAF3-5 414S302M-YAi 414S303M-YAi 414S603M-YAi 414S604M-YAi416S302M-YAi 416S303M-YAi 416S603M-YAi 416S604M-YAi In the case of other explosion-proof barriers and combination *1 Structure of the main valve Pilot spool type Pilot ceramic slide type Port size Rc1/4 Rc3/8 Rc1/2 Rc1/4 Rc3/8 Rc1/2 Effective area of valve 25mm2 30mm2 51mm2 60mm2 24mm2 28mm2 51mm2 60mm2 Working pressure 0.2~0.7MPa 0.12~0.7MPa Ambient temp. -5~50℃ -10~60℃ Explosion-proof standard Intrinsic safety construction Operating condition 1. Use with specified safety barrier. For Exia II BT5 explosion-proof valves, use them with the safety barrier SAF3-5 or that meets the conditions described below (note *1). 2. Parts and connections cannot be changed. 3. Use 1 explosion-proof barrier for each solenoid valve. note *1 In the case of other barriers and combination Konan 454, 414, 416 series intrinsic safety solenoid valves have passed equipment qualification tests for intrinsic safety solenoid valve. The valves can be used in combination with the safety barrier that meets the following conditions. (The valves can be used with insulation barrier that does not need type A ground.) The barrier used in combination with the valves should be the one that has passed equipment qualification tests for a barrier and that meets the following conditions. Safety retention voltage Maximum voltage of a intrinsic safety circuit Less than 29.4V Maximum current of a intrinsic safety circuit Less than 93.8mA Electric power of a intrinsic safety circuit Less than 0.689W Performance classification / Group Performance classification ia Group ⅡB or ⅡC Allowable inductance (Lo) and capacitance (Co) for an intrinsic safety circuit and relationship between inductance (Lo) and capacitance (Cw) for external connections to the intrinsic safety circuit Allowable inductance of a intrinsic safety circuit:Lo≧Li+Lw(mH) Allowable capacitance of a intrinsic safety circuit:Co≧Ci+Cw(μF) |
Packaging & Delivery
| Packaging: | Safe original packing |
|---|---|
| Delivery/Lead Time: | 7-10 days after payment |
| Production Capacity: | 2000 per month |
Product Description
Intrinsic safety valves can be used for applications that require similar explosion class/ignition degree to d2G4 or Exd II BT5 type (explosion-proof enclosure construction). Without need for expensive connection tools and complex installation work that are inevitable for explosion-proof enclosure types, the intrinsic safety valves achieve highly reliable explosion-proof performance.
Return Hold Kind of barrier to combine
454S202C 454S203C 454S403C 454S404C 454D202C 454D203C 454D403C 454D404C
SAF3-5
454S202M 454S203M 454S403M 454S404M 454D202M 454D203M 454D403M 454D404M
In the case of other explosion-proof barriers and combination *1
Structure of the main valve Pilot spool type
Port size
Rc1/4 Rc3/8 Rc1/2 Rc1/4 Rc3/8 Rc1/2
Effective area of valve 22mm2 40mm 22mm 40mm2
Working pressure 0.2~0.7MPa
Ambient temp. -5~50℃
Explosion-proof standard Intrinsic safety construction
Operating condition
Use with specified safety barrier
For i2G4 explosion-proof valves, use them with MTL728+ safety barrier.
For Exia II BT5 explosion-proof valves, use them with the safety barrier SAF3-5 or that meets the
conditions described below (note *1).
2. Parts and connections cannot be changed.
3. Use 1 explosion-proof barrier for each solenoid valve.
12. Konan Intrinsic Safety Solenoid Valves 414/416 series 5-port solenoid valves Terminal block ZA Spool valve/Ceramic slide valve
Return
Kind of barrier to combine
ExiaⅡBT5
SAF3-5
414S302M-YAi 414S303M-YAi 414S603M-YAi 414S604M-YAi416S302M-YAi
416S303M-YAi 416S603M-YAi 416S604M-YAi
In the case of other explosion-proof barriers and combination *1
Structure of the main valve Pilot spool type
Pilot ceramic slide type Port size
Rc1/4 Rc3/8 Rc1/2 Rc1/4 Rc3/8 Rc1/2
Effective area of valve
25mm2 30mm2 51mm2 60mm2 24mm2 28mm2 51mm2 60mm2
Working pressure 0.2~0.7MPa 0.12~0.7MPa
Ambient temp. -5~50℃ -10~60℃
Explosion-proof standard Intrinsic safety construction
Operating condition
1. Use with specified safety barrier.
For Exia II BT5 explosion-proof valves, use them with the safety barrier SAF3-5 or that meets the
conditions described below (note *1).
2. Parts and connections cannot be changed.
3. Use 1 explosion-proof barrier for each solenoid valve.
note *1
In the case of other barriers and combination
Konan 454, 414, 416 series intrinsic safety solenoid valves have passed equipment qualification tests for intrinsic safety solenoid valve.
The valves can be used in combination with the safety barrier that meets the following conditions. (The valves can be used with insulation barrier that does not need type A ground.)
The barrier used in combination with the valves should be the one that has passed equipment qualification tests for a barrier and that meets the following conditions.
Safety retention voltage
Maximum voltage of a intrinsic safety circuit
Less than 29.4V
Maximum current of a intrinsic safety circuit
Less than 93.8mA
Electric power of a intrinsic safety circuit
Less than 0.689W
Performance classification / Group
Performance classification
ia
Group
ⅡB or ⅡC
Allowable inductance (Lo) and capacitance (Co) for an intrinsic safety circuit and relationship between inductance (Lo) and capacitance (Cw) for external connections to the intrinsic safety circuit
Allowable inductance of a intrinsic safety circuit:Lo≧Li+Lw(mH)
Allowable capacitance of a intrinsic safety circuit:Co≧Ci+Cw(μF)
|
SUPPLIER PROFILE
|
|||
|---|---|---|---|
| Company: | Contranspower Co., Ltd | ||
| City/State | Chengdu, Sichuan | Country: |
China
|
| Business Type: | Export - Manufacturer / Trading Company | Established: | 2003 |
| Member Since: | 2020 | Contact Person | Rona Zhang |
SUPPLIER PROFILE
City/State/Country -
Chengdu, Sichuan
China 

Business Type -
Export - Manufacturer / Trading Company
Established -
2003
Member Since -
2020
Contact Person -
Rona Zhang