DDSY283 KEMA
Specifications:
1) Connection: direct or CT operated
2) Rated voltage: 220V
3) Optional voltage: 110/120/220/230/240V
4) Rated frequency: 50/60Hz
5) Starting current: 0.4% ib
6) Power loss in voltage loop: <= 1.5W, <= 8VA
7) Power loss in current loop: <= 0.3W
8) Accuracy: class 1
9) AC voltage test: 2kV/min
10) Impulse voltage test: 6kV
11) Standard: IEC 61036
LD68 KEMA
Specifications:
1) Nominal current (ib): 1.5, 2.5, 5, 10, 15, 20, 30A
2) Maximum current (Imax): 6, 10 or 15, 20 or 30, 40 or 60, 60 or 100, 80 or 100A
3) Transformer current (only for transformer-connected type): 5A, others directly-connected
4) Constant: 2,400, 1,440, 720, 600, 360, 240, 180, 120r/kW/h
5) Rated voltage (Un): 120/127/220/230/240V
6) Rated frequency (fn): 50 or 60Hz
7) Accuracy: class 2.0 (complying with IEC 60521)
8) Creep: 0.8-1.1Un
9) Starting current: 0.5% ib
10) Rotor torque at ib:
a) For 400% overload: 500u Nm
b) For 600% overload: 420u Nm
11) Rotor speed at ib:
a) For 400% overload: 13.2r/min
b) For 600% overload: 11r/min
12) Voltage coil loss at 50Hz, Un: 0.9W/4.8VA
13) Voltage coil loss at 50Hz, ib: 0.25W/0.3VA
14) AC voltage test 50Hz, 1min: 2.5kV
15) Impulse voltage test 1.2/50us: >6.5kV
16) Disk mass: 26g
17) Total meter mass: 1.3kg
HPT-01A KEMA
Specifications:
1) Voltage: 57.5/100V, 110/190V, 220/380V (-20% to +15%)
2) Current: 1.5 (6.0) A, 10 (60) A , 10 (100) A
3) Frequency: nominal 50Hz +/- 5 % (option: 60Hz +/- 5 %)
4) Accuracy: class 0.5, class 1 (for kW/h)
5) Starting current: < 0.001 In
6) Startup delay: < 3S from power application to pulse accumulation
7) Measurement: kW/h, kVar/h, max demand
8) Tariff: 4
9) Applicable standards: IEC 60687, IEC 61036, IEC 61107
10) With anti-tamper features
11) Operation software: Windows9X, WindowsXP
DT58 KEMA
Specifications:
1) Nominal current (ib): 1.5 or 3, 5, 10, 15, 20, 30A
2) Maximum current (Imax): 6, 20, 40 or 60, 60 or 100, 80 or 120, 100A
3) Transformer current (only for transformer-connected type): 5A, others directly connected
4) Constant: 600 or 450, 200, 100, 60, 50, 30r/kW/h
5) Rated voltage (Un): 3 x 57.7/100, 3 x 120/208, 3 x 220/380, 3 x 240/415V
6) Rated frequency (fn): 50 or 60Hz
7) Accuracy: class 2.0
8) Creep: 0.8-1.1 Un
9) Starting current: 0.5% ib
10) Rotor torque at ib: 400% ib: 850u Nm, 600% ib: 750u Nm
11) Rotor speed at ib: 9.9, 14.9, 11, 9.9
12) Voltage coil loss at 50Hz, Un: 1W/4.8VA
13) Voltage coil loss at 50Hz, ib: 0.3VA
14) AC voltage test 50Hz, 1 min: 2.5kV
15) Impulse voltage test 1.2/50us: > 6.5kV
16) Disk mass: 48g
17) Total meter mass: about 3.5kg
DDS28 KEMA
Specifications:
1) Connection: directly connected or CT/PT connected
2) Standard reference voltage: 220V
3) Optional reference voltage: 110/12/220/230/240V
4) Reference frequency: 50 or 60Hz
5) Starting current: 0.4% ib
6) Current power loss: < 0.3W
7) Voltage power loss: < 0.7W, < 6.0VA
8) Weight: 0.6kg
9) Accuracy: class 1%
10) AC voltage test: 2kV
11) Impulse voltage test: 6kV
12) Basic speed: 13.2r/min
HLD01 KEMA
Specifications:
1) Nominal current (ib): 1.5, 2.5, 3, 5, 10, 15, 20, 30A
2) Maximum current: 6. 10, 12, 20, 40, 60, 8, 100A
3) Constant: 2,400, 1,400, 1,200, 720, 360, 240, 180, 120r/kW/h
4) Rotor speed at ib: 13.2 r/min
5) Rotor torque at ib: 4.5 x 10-4N.m
6) Voltage consumption: 0.9/4W/VA
7) Overload capacity: 400% ib
8) Accuracy: class 2.0
9) Service life: 10 years
10) Rated voltage (Un): 220V
11) Rated frequency (fn): 50Hz
12) Voltage coil loss at 50Hz, Un: 1.0W/5VA
13) Current coil loss at 50Hz, ib: 0.3VA
14) Creep: 0.8-1.1Un
15) Starting current: 0.5% ib
16) AC voltage 50Hz, 1 min:
a) Between line and earth: 2.5kV
b) Between line: 600V
17) Impulse voltage 1.2/50us: > 6kV
18) Rotor mass: 24g
19) Total meter mass: 1.5-1.6kg
HLD03 KEMA single phase electromechanical meter
Specifications:
1) Nominal current (ib): 1.5, 2.5, 5, 10, 15A
2) Maximum current (Imax): 6, 10 or 15, 20 or 30, 40 or 60, 60 or 100A
3) Thermal capacity: ib and Imax (A)
4) Reference voltage: 120/127/220/230/240V
5) Reference frequency: 50 or 60Hz
6) Voltage consumption: 0.9/4W/VA
7) Current consumption: 0.4VA
8) Creep: 0.8-1.1Un
9) Starting: <=0.5% ib (A)
10) AC voltage test: 2kV
11) Impulse voltage test: 6kV
12) Basic speed: 13.2r/min
SUPPLIER PROFILE
|
|||
---|---|---|---|
Company: | Holley Group Co., Ltd | ||
City/State | Hangzhou, Zhejiang | Country: |
China ![]() |
Business Type: | Export - Manufacturer / Trading Company | Established: | NA |
Member Since: | 2005 | Contact Person | DavidWang |
SUPPLIER PROFILE
City/State/Country -
Hangzhou, Zhejiang
China 

Business Type -
Export - Manufacturer / Trading Company
Established -
NA
Member Since -
2005
Contact Person -
DavidWang